Product Description


This is a simple-to-use hydrogen gas sensor, suitable for sensing hydrogen concentrations in the air. The MQ-8 can detect hydrogen gas concentrations anywhere from 100-10000ppm. This sensor has a high sensitivity and fast response time. The sensor’s output is an analog resistance. The drive circuit is very simple; all you need to do is power the heater coil with 5V, add a load resistance, and connect the output to an ADC.

Specifications:
Detection Range: 100-10000ppm
Heater Voltage: 5.0 ±0.1V AC or DC
Heater Current: <= 900mA





Click here to read the California regulatory warning.